The test probe is carried out with a test probe similar to that of test probe B of IEC 61032 but having a circular stop face with a diameter of 125 mm instead of the non-circular face, the distance be
IEC Standard Articulated Test Probe is a precision test probe made according to Figure 2 (Fig. 2) of the IEC 61032 (Test probe B) and is used to simulate a human finger. It is also used by the standar
Rigid Test Finger Probe is a precision test probe made according to Figure 7 (Fig. 7) of the IEC 61032 (Test probe 11) and is used to simulate a human finger. It is also used by the standards of CSA,
IEC 61032 Figure 13 – Test probe 19 (small finger probe ∅ 5,6mm)
This probe is intended to simulate access to hazardous parts by children of 36 months or less.
The Jointed Test Finger & Unjointed Test Finger is a precision test probe made according to Figure 2 (Test Probe B) and Figure 7 (Test Probe 11) of the IEC 61032 is used to simulate a human finger, us
The Rigid Test Finger is a precision test probe made according to Figure 7 (Fig. 7) of the IEC 61032 (Test probe 11) and IEC 61010-1 is used to simulate a human finger.
IP2X Test Finger Probe is a precision test probe made according to Figure 2 (Fig. 2) of the IEC 61032 (Test probe B) and IEC60529 is used to simulate a human finger.
IEC 61032 Figure 12 – Test probe 18 (small finger probe ∅ 8,6mm)
This probe is intended to simulate access to hazardous parts by children of more than 36 months and less than 14 years.
The Rigid Test Finger is a precision test probe made according to Figure 7 (Fig. 7) of the IEC 61032 (Test probe 11) and is used to simulate a human finger. It is also used by the standards of CSA, IR
The test probe is carried out with a test probes similar to that of test probe B of IEC 61032 but having a circular stop face with a diameter of 125mm and thickness of 80mm instead of the non-circular
The Rigid Test Finger is a precision test probe made according to Figure 7 (Fig. 7) of the IEC 61032 (Test probe 11) and is used to simulate a human finger. It is also used by the standards of CSA, IR
The Jointed Test Finger is a precision test probe made according to IEC 60238 Figure 16 and IEC 61032 Figure 2 (Test probe B) and is used to simulate a human finger. It is also used by the standards o
IP2X Test Finger Probe is a precision test probe made according to Figure 2 (Fig. 2) of the IEC 61032 (Test probe B) and is used to simulate a human finger. It is also used by the standards of CSA, IR